Bedside Panel System is a Microcontroller based room management system. The supplied revision of the product consists of panels based on feather touch switches and is capable of controlling all electrical appliances inside guest rooms.  Infrared key tag holder, corridor panels, RF remote and bathroom switch panel, door chime, temperature sensor and main controller are also supplied along with the system.

The colour scheme of the panel, switches and the layouts of the switches are as per the design furnished by you.  The integrated clock in the bedside controller panel is capable of displaying the set temperature of the room (temperature set mode).  Room service controls like Laundry and Clean my room Do not disturb, a separate master control switches are integrated to the bedside controller panel.

 
v

Feather touch switch panels.

v

Total privacy to guest.

v

AC will be off if window or bath room door is open.

v

Key tag holder automatically switches �ON� all lights (except night lamp and bathroom lamp) when key (guest or staff) is inserted in the holder.

v All lights and the appliances can be controlled from one locations using control panels
v Bathroom switch (separate panel) can be operated independently in master mode. When 'master' switch is 'ON' all lamps will be switched off (except night lamp and bed lamp).
v All the switches �ON� the panel can switch �OFF� (reset) the 'Master' switch. On resetting the 'Master' switch, Rack lamp and Bed lamp will be switched �ON�.
v Fine control of room temperature- 18�C to 28�C in1�C step.
v When Eco Switch is pressed the room temperature will be maintained at 240C, and temperature up/down switch will not function.
v When key tag is taken out, immediately uncontrolled lights will be switched �OFF� and all controlled lights will switch �OFF� after a 20 sec delay. The AC unit will be switched to low speed mode and a 24ºC room temperature will be maintained.
v When the key tag is inserted, FCU speed will be set to 'Medium' condition and the temperature will be set to 22�C.
v In bypass mode vestibule, table, window and bathroom switch will be switched ‘ON’ and FCU will be kept in the low speed.
v Do not disturb signal will be deactivated if a service call is initiated. This signal will not be activated if service calls are active.
v If Do not disturb mode is set and if somebody presses the Bell switch in the corridor panel, the DO NOT DISTURB indication will blink.
v Service calls and DO NOT DISTURB are indicated in the corridor panel.